About this item
PL e - SIL 3 safety speed monitoring interfaceSafety speed monitoring interfaces. Safety level up to PL e - SIL 3
SV MR0 - Safety speed monitoring relay for Overspeed and Zero speed controlSV MR0 U - Safety speed monitoring relay for Underspeed controlBoth modules integrate:
Guided-contact safety relaySelectable manual orAutomatic restartEDM feedback input for external contactors monitoringEnable inputs used, for instance, when monitoring the same axis, in different working phases, with more modules configured with different thresholds
Faults are signalled by LED Fault and a PNP system status output. PNP status output indicating overspeed or underspeed thresholds crossing
SV MR0 and SV MR0 U integrates:
2 inputs for PNP proximities switches3 front panel selectors allow configuration of the speed threshold
Compliance
-
- 2006/42/EC: Machine Directive
- 2014/30/EU: Electromagnetic Compatibility Directive
- 2014/35/EU: Low Voltage Directive
- EN ISO 13849-1:2008 (Cat.4, PL e) Safety of machinery. Safety-related parts of control systems. Part 1: General principles for design
- EN 61508-1:2010 (SIL 3) Functional safety of electrical/electronic programmable electronic safety related systems. General requirements
- EN 61508-2:2010 (SIL 3) Functional safety of electrical/electronic/programmableelectronic safety related systems. Requirements for electrical/electronic/programmable electronic safety-related systems
- EN 61508-3:2010 (SIL 3) Functional safety of electrical/electronic programmable electronic safety related systems: Software requirements
- EN 61508-4:2010 (SIL 3) Functional safety of electrical/electronic programmable electronic safety related systems. Definitions and abbreviations
- EN 62061:2005 (SILCL 3) Safety of machinery. Functional safety of safety-related electrical, electronic and programmable electronic control systems